Structured wiring

Structured wiring for a new home: what to pre-wire

Where to run Ethernet, conduit and coax before the drywall goes up, and what to ask your builder for.

How we know: based on IEEE 802.3 task force objectives, TIA guidance as summarized by Fluke Networks, cable maker data sheets, Comcast builder pre-wire specifications, the RouterHaus coverage model, checked . RouterHaus didn't test this hands-on.

How it was checked: its claims were checked against the sources listed below by an AI fact-checker working separately from the writer, on . No named human editor has reviewed it. How we produce articles.

Illustration: a cutaway of a two-floor home with network cables running from rooms, including a ceiling access point, a TV wall and a desk, back to a network closet with a switch.
Illustration: RouterHaus

TL;DR: pull it once, while the walls are open

  • Home-run Ethernet from each room to one central network closet. Cat6a for access points and media walls; Cat6 is fine for short runs to bedrooms.
  • Ceiling drops for access points on every floor, positioned where people actually use Wi-Fi.
  • Conduit from where the internet service enters the house to the closet, and between floors, so cables can be added later without opening walls.
  • A closet with power and airflow, inside conditioned space, with room for the modem or fiber terminal, router and a switch.
Goal: reliable coverage on move-in day and an easy upgrade path later, without cutting drywall. Already moved in? See running Ethernet in an existing home.

Why pre-wire at all

  • Wired access points solve coverage properly. Access points connected by Ethernet give each area its own radio without spending airtime on wireless links between nodes. See mesh vs single router for why wired backhaul matters, and why mesh alone doesn’t fix slow rooms.
  • Stationary devices don’t need Wi-Fi. TVs, consoles, desktops and network storage work best on a cable and leave airtime for phones and laptops.
  • Upgrades stay cheap. Spare drops and conduit make it easy to move to faster internet, add cameras or replace access points years from now.

What to run: Ethernet, conduit, coax, fiber

  • Ethernet: drops to the office, media wall, TV locations, ceiling access point spots, garage or workshop, and any exterior camera locations.
  • Conduit or microduct: from the utility entry point to the closet, between floors, and to hard-to-reach soffits, with a pull string left inside. Your ISP can pull its own fiber or coax through it later.
  • Coax (RG-6): to the media wall and the closet. Some ISPs still deliver service over coax; Comcast’s builder specification, for example, calls for RG-6 tri-shield coax for drops up to 150 ft. Coax can also carry network traffic with MoCA adapters if Ethernet is missing somewhere (MoCA Alliance).
  • Fiber (optional): a spare single-mode fiber from the entry point to the closet, or to an office, is an option if conduit is not practical. Ask your ISP how it terminates fiber in your area first.

Suggested drops by room

These are starting points, not requirements. Adjust for how you live and where furniture will go.

LocationEthernetCoaxNotes
Home office / den2–40–1Desk, printer, spare; consider one on each likely desk wall
Living room / media wall2–31TV, console, streaming box
Primary bedroom1–20–1TV wall plus a spare
Other bedrooms10Desk or TV wall
Kitchen0–10Smart display or hub location
Garage / workshop1–20Access point, camera hub, EV charger with network features
Ceiling access point spots1 per planned access point0Powered over Ethernet (PoE) from the closet switch
Exterior eavesAs needed0Cameras or outdoor access points; use outdoor-rated cable or conduit
How many access points? Our rule of thumb is roughly one access point per 1,800 sq ft with drywall walls, 1,400 with plaster and 1,000 with block, brick, stucco or concrete, and at least one per floor in multi-floor homes over about 1,200 sq ft. It is an estimate, not a survey; see our methodology. Pull an extra drop or two at likely spots so you can adjust after move-in.
Home runs from each room to the network closetA house with an office, a living room and a bedroom above a network closet. Every network drop is its own cable back to a PoE switch in the closet, which also holds the router and the modem or fiber terminal, with conduit out to where the internet service enters. Office: a ceiling access point plus 2 to 4 desk drops. Living room: a ceiling access point plus 2 to 3 drops and RG-6 coax at the media wall. Bedroom: 1 to 2 drops at the TV wall. Each ceiling access point has one drop and is powered over Ethernet from the closet switch. Cat6a goes to access points, the media wall and the office; Cat6 is fine for short runs. Every drop is its own cable back to the closet Cat6a to access points, media wall and office; Cat6 fine for short runs Office Ceiling AP + desk: 2–4 drops Living room AP + media wall: 2–3 + coax Bedroom TV wall: 1–2 drops Network closet Ceiling AP Ceiling AP PoE switch Router Modem / ONT Conduit to the utility entry Home runs from each room to the network closetA house with an office, a living room and a bedroom above a network closet. Every network drop is its own cable back to a PoE switch in the closet, which also holds the router and the modem or fiber terminal, with conduit out to where the internet service enters. Office: a ceiling access point plus 2 to 4 desk drops. Living room: a ceiling access point plus 2 to 3 drops and RG-6 coax at the media wall. Bedroom: 1 to 2 drops at the TV wall. Each ceiling access point has one drop and is powered over Ethernet from the closet switch. Cat6a goes to access points, the media wall and the office; Cat6 is fine for short runs. Every drop is its own cable back to the closet Cat6a to APs, media wall and office; Cat6 fine for short runs Office Ceiling AP + desk: 2–4 drops Living room AP + media wall: 2–3 + coax Bedroom TV wall: 1–2 drops Network closet Ceiling AP Ceiling AP PoE switch Router Modem / ONT Conduit to utility entry
Each drop from the table is a separate cable back to one switch in the network closet, including one per ceiling access point, which the switch powers over Ethernet. Conduit from the closet to the utility entry leaves room for the provider's line later. Diagram: RouterHaus

Pre-wiring for access points

  • Ceiling-centered drops in main living areas, the upstairs landing and the office. Ceiling mounting avoids furniture and puts the radio above most obstructions.
  • Power over Ethernet: plan a closet switch with enough PoE ports and total power budget for every access point and camera. Check each access point’s data sheet for whether it needs PoE+ or the higher-power four-pair PoE defined in IEEE 802.3bt.
  • Wired backhaul: in a new build there is little reason to rely on wireless links between access points.
  • 6 GHz: most 6 GHz access points run under the FCC’s low-power indoor rules (Cisco), so the band usually reaches less far than 5 GHz. Access points close to where people sit get the most from it, which ceiling placement in each main area helps with.
  • Outbuildings: casitas, detached garages and pool houses usually need their own access point fed by a buried, outdoor-rated cable or conduit (see the large-property plan).

The network closet

  • Location: central and inside conditioned space. Avoid hot garages and attics.
  • Power: outlets inside the closet for the modem or fiber terminal, router, switch and a small battery backup. Your electrician will decide the circuits.
  • Space: a structured media enclosure or small wall-mount rack, with room to grow and service loops left on every cable. If the enclosure will hold the router or an access point, choose one that doesn’t block Wi-Fi: Comcast’s builder specification calls for a Wi-Fi-transparent engineered-plastic panel when it houses network equipment.
  • Airflow: a louvered door or ventilation; a PoE switch and router together produce noticeable heat (how to work out a closet's heat load).
  • Speed: if you might ever have internet faster than 1 Gbps, plan for a router and switch with multi-gig (2.5 Gbps or faster) ports. The router buying guide explains port speeds.
A rack-mounted patch panel with numbered ports, two of them fitted with Cat6 jacks, above a network switch with black patch cords plugged in and green link lights.
A patch panel above a PoE switch, the core of most network closets: each in-wall run ends at a numbered panel port, and switch ports labelled PoE+ (1 to 12 on this one) can power ceiling access points over their cables. Photo: Vladimir Srajber, via Pexels

Cat6 vs Cat6a

SpeedCat5eCat6Cat6a
2.5 GbpsUp to 100 mUp to 100 mUp to 100 m
5 GbpsUp to 100 m in defined deploymentsUp to 100 mUp to 100 m
10 GbpsNot specifiedUp to 37 m; 37 to 55 m depending on crosstalk between cablesUp to 100 m

The 2.5 and 5 Gbps figures are the IEEE 802.3bz objectives; 10 Gbps figures are from TIA TSB-155 and the Cat6A specification as summarized by Fluke Networks.

  • Cat6a: designed to support 10GBASE-T over the full 100 m channel (Fluke Networks). A sensible choice for access points, media walls and the office.
  • Cat6: TIA’s bulletin TSB-155 says 10GBASE-T “should operate over channel lengths of up to 37 meters of Category 6 cabling,” and between 37 and 55 m depending on interference between neighboring cables (alien crosstalk), as quoted by Fluke Networks. For 1, 2.5 and 5 Gbps it covers typical home runs: the IEEE 802.3bz task force set 100 m on Cat6 as its 5 Gbps objective and 100 m on Cat5e for 2.5 Gbps (IEEE 802.3bz objectives).
  • Cat6a is usually thicker. Belden lists 0.300 in for its 2148A Cat6A cable against 0.224 in for its 2412 Cat6; reduced-diameter Cat6A cables exist. Tell your installer early; standard Cat6A needs more room in walls, boxes and the panel.
  • Coax: RG-6 for ISP service and MoCA.
The back of a square metal-framed wall outlet with two orange cables; their coloured wires are pressed into two rows of white contacts beside a printed colour chart, with foil shields clamped under metal straps.
The back of a Cat6 wall outlet with two shielded runs terminated: each cable's four twisted pairs go into contacts in the colour order printed on the outlet (EIA/TIA 568), the step your installer should test on every run. Photo: www.heimnetzwerke.net, CC BY 4.0, via Wikimedia Commons (cropped to the outlet)

Code, permits and who installs

Low-voltage wiring is covered by the electrical and fire codes your area has adopted and by local rules that vary by state and city, including whether the installer must be licensed. Providers point to the same codes: Comcast’s builder specification requires installations to comply with federal, state and local fire and safety codes, including the National Electrical Code, and asks builders to provide a connection to the home’s electrical ground for its coax entry box. Ask your builder or a licensed low-voltage contractor what applies where you live. To estimate and compare installer quotes, use our wiring cost worksheet. Points to raise with them:

  • Separation between network cable and electrical wiring, as your local code and the cable maker’s instructions require.
  • Cable listed for the space it passes through (for example riser or plenum ratings where required).
  • Firestopping where cables pass through fire-rated walls or floors.
  • Grounding at the point where the provider’s coax enters the house.
  • Labeling both ends of every run, and testing each run after installation with results handed over.
  • Outdoor runs in conduit or with outdoor-rated cable.

RouterHaus plans networks; we do not install cabling, pull permits or provide engineering sign-off.

Checklist for your builder

  1. Mark access point locations on the plan: at least one per floor, plus outbuildings.
  2. Count drops per room using the table above; add spares at the office and media wall.
  3. Choose cable: Cat6a to access points, media and office; Cat6 or Cat6a elsewhere; RG-6 to media and closet.
  4. Specify the closet: location, outlets, ventilation and enclosure or rack size.
  5. Call out conduit: utility entry to closet, between floors, exterior camera spots, each with a pull string.
  6. Require labels and testing for every run, with results provided at handover.
Easy to miss: no outlet in the closet, no ceiling access point drops, a closet with no airflow, and no conduit from the utility entry. All are easy on paper and costly after drywall.

Getting help with the plan

Our small business and builder consultation produces a cabling and access point plan you can add to drawings, an equipment list and rack layout, and coordination notes for your electrician or low-voltage contractor. It is remote, with on-site walkthroughs available in the Phoenix metro, where block and stucco construction makes access point planning especially important. Installation itself is done by your builder’s trades.

Talk to us about your build Send your floor plan

Frequently asked questions

Cat6 or Cat6a for new construction?

Cat6a for access points, the media wall and the office, because it supports 10 Gbps over full-length runs (up to 100 m). Cat6 is fine for shorter runs to bedrooms and anything that will stay at 1, 2.5 or 5 Gbps.

Do I still need coax in a new house?

It is worth running RG-6 to the media wall and the network closet. Some ISPs deliver service over coax, and MoCA adapters can use coax as a network link where Ethernet is missing.

How many access points should I plan?

Start with about one per 1,800 sq ft with drywall walls, 1,400 with plaster and 1,000 with block, brick, stucco or concrete, and at least one per floor in multi-floor homes over about 1,200 sq ft. Pull a spare drop or two so you can adjust after move-in.

Is wireless backhaul okay in a new build?

It works, but a new build is the easiest time to run Ethernet to every access point. Wired links are faster and more consistent and keep the airtime free for your devices.

What should go in the network closet?

Power outlets, ventilation, the ISP modem or fiber terminal, the router, a PoE switch sized for your access points and cameras, a patch panel with labeled runs, and ideally a small battery backup.

Does the installer need a license?

It depends on your state and city. Ask your builder or local licensing authority before work starts. RouterHaus provides planning only and does not install cable or sign off on drawings.

Sources

Read on October 21, 2026.

Your privacy choices

RouterHaus uses Google Analytics to understand which pages help people. We don't sell personal information. Advertising cookies are off.

Until you save a choice here, analytics cookies are off for visitors in the EEA, UK and Switzerland and in browsers that send Global Privacy Control; elsewhere they're on. When they're off, Google may still receive cookieless pings without identifiers. A choice you save here applies in this browser wherever you are, and your analytics choice applies even if the browser sends Global Privacy Control.

Details are in our privacy policy.