Business reference design

Warehouse

A conceptual layout for a high-bay warehouse: a firewall, a PoE switch and access points chosen for mounting height and rack aisles, plus coverage at the loading dock. High shelving and stored goods change coverage more than floor area does, so the access-point roles here are placeholders until a survey sets them.

Conceptual reference architecture, not a validated design. It names roles and requirements, not validated models, and carries no total price.

Engine result
Conceptual
Parts
No total conceptual design
Wi-Fi units
10 in this design; rule of thumb for the stated space: 8 (an estimate)
Slowest wired link
1 Gbps link rate, not throughput
PoE allocated
300 W IEEE class allocations
Checks
12 1 OK, 1 notes, 0 need equipment, 10 unverified, 0 incompatible

The builder link carries the whole design in the part of the address after "#", which your browser does not send to our server. A shorter link loads this design by name: www.routerhaus.com/build#design=warehouse.

Assumptions

The design was drawn for these inputs. They are assumptions about a typical site, not facts about yours; change them in the builder and every check runs again.

  • Assumption: about 40,000 sq ft open floor with high ceilings and racked aisles.
  • Assumption: handheld scanners and tablets that roam across the floor (about 60 Wi-Fi devices).
  • Assumption: one equipment room near the office.

Internet: Internet 500 Mbps down (primary).

Diagram

Each line is labelled with its link rate (the slower of its two ports), the cable and any PoE allocation. A marker and a letter flag a link or device that needs attention; colour is never the only sign.

Warehouse: network diagramNetwork diagram: 1 internet connection, 4 devices. Check result: Unverified: needs confirmation. Each device lists how it is powered and its link upstream; link rates are Ethernet link rates, not throughput.Internet 500 Mbps down ? Firewall or gateway Office and equipment room ? PoE access switch, 24 ports, 802.3at, Office and equipment roomPoE access switch, 24 po… Office and equipment room ? 8 x High-ceiling access point with directional or narrow-beam antennas, Warehouse floor (high ceiling)8 x High-ceiling access… Warehouse floor (high ceiling) ? 2 x Access point rated for the dock's temperature and dust, Loading dock2 x Access point rated f… Loading dock ? 60 Wi-Fi devices Counted in the design +
Warehouse: network diagramNetwork diagram: 1 internet connection, 4 devices. Check result: Unverified: needs confirmation. Each device lists how it is powered and its link upstream; link rates are Ethernet link rates, not throughput.Internet 500 Mbps down ? Firewall or gateway Office and equipment room ? PoE access switch, 24 ports, 802.3at, Office and equipment roomPoE access switch, 24 po… Office and equipment room ? 8 x High-ceiling access point with directional or narrow-beam antennas, Warehouse floor (high ceiling)8 x High-ceiling access… Warehouse floor (high ceiling) ? 2 x Access point rated for the dock's temperature and dust, Loading dock2 x Access point rated f… Loading dock ? 60 Wi-Fi devices Counted in the design +
Warehouse: devices by location, with link rates. A text version follows.
Text version of the diagram
  1. Warehouse
    1. Office and equipment room
      1. Internet, internet connection, 500 Mbps down, connects to Firewall or gateway, status: Unverified: needs confirmation
        1. Firewall or gateway, Office and equipment room, power not stated, link of unknown speed to Internet, status: Unverified: needs confirmation
          1. PoE access switch, 24 ports, 802.3at, Office and equipment room, power not stated, 1 Gbps link over Cat6 to Firewall or gateway, status: Unverified: needs confirmation
            1. 8 x High-ceiling access point with directional or narrow-beam antennas, Warehouse floor (high ceiling), powered by PoE+ from PoE access switch, 24 ports, 802.3at, speed not known links, status: Unverified: needs confirmation
            2. 2 x Access point rated for the dock's temperature and dust, Loading dock, powered by PoE+ from PoE access switch, 24 ports, 802.3at, speed not known links, status: Unverified: needs confirmation
  2. No site given
    1. Location not given
      1. 60 Wi-Fi devices, counted in the design, no Wi-Fi device in the design to connect to

Connections

Connections in the Warehouse design
FromToCableLink ratePowerResult
InternetFirewall or gatewayRJ45 handoffNot knownNoneUnverified: needs confirmation
Firewall or gatewayPoE access switch, 24 ports, 802.3atCat61 GbpsNoneCompatible
PoE access switch, 24 ports, 802.3at8 x High-ceiling access point with directional or narrow-beam antennasCat68 x speed not knownPoE+ (802.3at), 240 W allocated (8 x 30 W)Unverified: needs confirmation
PoE access switch, 24 ports, 802.3at2 x Access point rated for the dock's temperature and dustCat62 x speed not knownPoE+ (802.3at), 60 W allocated (2 x 30 W)Unverified: needs confirmation

Roles and requirements

Conceptual reference architecture, not a validated design. A role without a model states what the part must do; where the design names a catalogued model, it is an example that meets the role, not a recommendation.

Roles in the Warehouse design
RoleRequirementExample modelQty
FirewallFirewall or gatewayNo model named1
SwitchPoE access switch, 24 ports, 802.3atNo model named1
Access pointHigh-ceiling access point with directional or narrow-beam antennasNo model named8
Access pointAccess point rated for the dock's temperature and dustNo model named2

Also needed, not priced: 11 × cat6 cable run. Cable lengths are not part of the design.

Checks

What the Network Builder's rules found when they compared every part with the others. Each result says what it is based on: the maker's documentation, a standard, a RouterHaus calculation or an estimate. We have not tested this equipment.

Ports, cables and link rates

  • Unverified Link rate between the internet connection and Firewall or gateway (Office and equipment room) is not known

    No speed is published for Firewall or gateway port, so the rate of the link between the internet connection and Firewall or gateway (Office and equipment room) cannot be worked out. Confirm the port speed on the maker's datasheet.

    Basis: RouterHaus calculation. Source: ieee802.org

  • OK 1 wired link rated

    Wired links: 1 at 1 Gbps. Each is the slower of its two ports, capped by the cable where a type and length were given. These are Ethernet link rates, not throughput: real transfers are lower and depend on the devices at each end.

    Basis: RouterHaus calculation. Source: ieee802.org

  • Unverified Firewall or gateway (Office and equipment room): WAN port speed not published

    No speed is published for Firewall or gateway (Office and equipment room)'s WAN port, so we cannot say whether it carries the 500 Mbps Internet plan. Confirm the port speed on the maker's datasheet.

    Basis: Requirement stated in the design (no model chosen)

Power and PoE

  • Unverified PoE access switch, 24 ports, 802.3at (Office and equipment room): PoE budget not published

    No PoE budget is published for PoE access switch, 24 ports, 802.3at (Office and equipment room). This design allocates 8 x High-ceiling access point with directional or narrow-beam antennas (Warehouse floor (high ceiling)) at 30 W (802.3at) and 2 x Access point rated for the dock's temperature and dust (Loading dock) at 30 W (802.3at), 300 W in total. Confirm the budget on the maker's datasheet before relying on it.

    Basis: RouterHaus calculation. Source: ieee802.org

  • Unverified High-ceiling access point with directional or narrow-beam antennas (Warehouse floor (high ceiling)): power draw not published

    No maximum power draw is published for High-ceiling access point with directional or narrow-beam antennas (Warehouse floor (high ceiling)). It is allocated 30 W as an 802.3at device, but without the draw figure we cannot confirm that class is enough. Check the maker's datasheet.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Access point rated for the dock's temperature and dust (Loading dock): power draw not published

    No maximum power draw is published for Access point rated for the dock's temperature and dust (Loading dock). It is allocated 30 W as an 802.3at device, but without the draw figure we cannot confirm that class is enough. Check the maker's datasheet.

    Basis: Requirement stated in the design (no model chosen)

Management

  • Unverified Firewall or gateway (Office and equipment room): VLAN support not documented

    This design asks for VLANs. No model is chosen for Firewall or gateway (Office and equipment room), so separate networks cannot be confirmed on it.

    Basis: Requirement stated in the design (no model chosen)

Catalog data

  • Note No listed price for 4 parts

    No price from the maker's own store or price list is on record for: 1 x Firewall or gateway (no model chosen), 1 x PoE access switch, 24 ports, 802.3at (no model chosen), 8 x High-ceiling access point with directional or narrow-beam antennas (no model chosen) and 2 x Access point rated for the dock's temperature and dust (no model chosen). The parts total leaves them out, so it is a lower bound, not the full cost. We do not fill gaps with retailer prices.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Firewall or gateway (Office and equipment room): no model chosen

    Firewall or gateway (Office and equipment room) is a role without a model. The checks use what was entered for it (5 ports), which is a requirement, not a maker's published specification. Not known: model, price, port speeds and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified PoE access switch, 24 ports, 802.3at (Office and equipment room): no model chosen

    PoE access switch, 24 ports, 802.3at (Office and equipment room) is a role without a model. The checks use what was entered for it (28 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified High-ceiling access point with directional or narrow-beam antennas (Warehouse floor (high ceiling)): no model chosen

    High-ceiling access point with directional or narrow-beam antennas (Warehouse floor (high ceiling)) is a role without a model. The checks use what was entered for it (PoE input), which is a requirement, not a maker's published specification. Not known: model, price, ports and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Access point rated for the dock's temperature and dust (Loading dock): no model chosen

    Access point rated for the dock's temperature and dust (Loading dock) is a role without a model. The checks use what was entered for it (PoE input), which is a requirement, not a maker's published specification. Not known: model, price, ports and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

Installation

  • Access points mounted at the height and angle the survey specifies, often below the roof structure and above aisles.
  • Long runs may need a second closet or fiber to stay within 100 m copper limits.
  • Lifts or scissor lifts for mounting; plan safety and access.

Security and segmentation

  • Staff (suggested VLAN 10): office computers.
  • Devices (suggested VLAN 40): scanners, printers and warehouse systems, reachable only from the systems that manage them.
  • Guest (suggested VLAN 30): drivers and visitors, internet only.
Networks in the Warehouse design
VLANNamePurpose
staffStaffCompany laptops and desks
devicesDevicesPrinters and shared devices; reachable from Staff
guestGuestVisitors; internet only

Upgrade paths

  • A second switch closet with fiber uplinks for the far end of the building.
  • Outdoor yard coverage after checking 6 GHz outdoor rules.

Risks and limits

  • Conceptual: the access points and switch are roles; RF coverage among racking needs an on-site survey.
  • Inventory changes (full or empty racks) change coverage.
  • Cable lengths across a large floor are not checked.

Sources

Maker documents and standards this design was drawn from:

Cited by the checks:

Design data updated . Prices and specifications come from the RouterHaus catalog; see how we work.

Next steps

Make it yours

Open the design in the builder, change the space, the internet plan or any part, and the checks and total update.

Open in the builder

More business designs

Questions that decide the architecture, the tools and the equipment for this kind of site.

Business solutions · All designs

Expert help

Request a consultation and paste the builder link into the notes, so the review starts from this design.

Request a review

Related guides

Your privacy choices

RouterHaus uses Google Analytics to understand which pages help people. We don't sell personal information. Advertising cookies are off.

Until you save a choice here, analytics cookies are off for visitors in the EEA, UK and Switzerland and in browsers that send Global Privacy Control; elsewhere they're on. When they're off, Google may still receive cookieless pings without identifiers. A choice you save here applies in this browser wherever you are, and your analytics choice applies even if the browser sends Global Privacy Control.

Details are in our privacy policy.