Business reference design
Warehouse
A conceptual layout for a high-bay warehouse: a firewall, a PoE switch and access points chosen for mounting height and rack aisles, plus coverage at the loading dock. High shelving and stored goods change coverage more than floor area does, so the access-point roles here are placeholders until a survey sets them.
Conceptual reference architecture, not a validated design. It names roles and requirements, not validated models, and carries no total price.
- Engine result
- Conceptual
- Parts
- No total conceptual design
- Wi-Fi units
- 10 in this design; rule of thumb for the stated space: 8 (an estimate)
- Slowest wired link
- 1 Gbps link rate, not throughput
- PoE allocated
- 300 W IEEE class allocations
- Checks
- 12 1 OK, 1 notes, 0 need equipment, 10 unverified, 0 incompatible
The builder link carries the whole design in the part of the address after "#", which your browser does not send to our server. A shorter link loads this design by name: www.routerhaus.com/build#design=warehouse.
Assumptions
The design was drawn for these inputs. They are assumptions about a typical site, not facts about yours; change them in the builder and every check runs again.
- Assumption: about 40,000 sq ft open floor with high ceilings and racked aisles.
- Assumption: handheld scanners and tablets that roam across the floor (about 60 Wi-Fi devices).
- Assumption: one equipment room near the office.
Diagram
Each line is labelled with its link rate (the slower of its two ports), the cable and any PoE allocation. A marker and a letter flag a link or device that needs attention; colour is never the only sign.
Text version of the diagram
- Warehouse
- Office and equipment room
- Internet, internet connection, 500 Mbps down, connects to Firewall or gateway, status: Unverified: needs confirmation
- Firewall or gateway, Office and equipment room, power not stated, link of unknown speed to Internet, status: Unverified: needs confirmation
- PoE access switch, 24 ports, 802.3at, Office and equipment room, power not stated, 1 Gbps link over Cat6 to Firewall or gateway, status: Unverified: needs confirmation
- 8 x High-ceiling access point with directional or narrow-beam antennas, Warehouse floor (high ceiling), powered by PoE+ from PoE access switch, 24 ports, 802.3at, speed not known links, status: Unverified: needs confirmation
- 2 x Access point rated for the dock's temperature and dust, Loading dock, powered by PoE+ from PoE access switch, 24 ports, 802.3at, speed not known links, status: Unverified: needs confirmation
- PoE access switch, 24 ports, 802.3at, Office and equipment room, power not stated, 1 Gbps link over Cat6 to Firewall or gateway, status: Unverified: needs confirmation
- Firewall or gateway, Office and equipment room, power not stated, link of unknown speed to Internet, status: Unverified: needs confirmation
- Internet, internet connection, 500 Mbps down, connects to Firewall or gateway, status: Unverified: needs confirmation
- Office and equipment room
- No site given
- Location not given
- 60 Wi-Fi devices, counted in the design, no Wi-Fi device in the design to connect to
- Location not given
Connections
| From | To | Cable | Link rate | Power | Result |
|---|---|---|---|---|---|
| Internet | Firewall or gateway | RJ45 handoff | Not known | None | Unverified: needs confirmation |
| Firewall or gateway | PoE access switch, 24 ports, 802.3at | Cat6 | 1 Gbps | None | Compatible |
| PoE access switch, 24 ports, 802.3at | 8 x High-ceiling access point with directional or narrow-beam antennas | Cat6 | 8 x speed not known | PoE+ (802.3at), 240 W allocated (8 x 30 W) | Unverified: needs confirmation |
| PoE access switch, 24 ports, 802.3at | 2 x Access point rated for the dock's temperature and dust | Cat6 | 2 x speed not known | PoE+ (802.3at), 60 W allocated (2 x 30 W) | Unverified: needs confirmation |
Roles and requirements
Conceptual reference architecture, not a validated design. A role without a model states what the part must do; where the design names a catalogued model, it is an example that meets the role, not a recommendation.
| Role | Requirement | Example model | Qty |
|---|---|---|---|
| Firewall | Firewall or gateway | No model named | 1 |
| Switch | PoE access switch, 24 ports, 802.3at | No model named | 1 |
| Access point | High-ceiling access point with directional or narrow-beam antennas | No model named | 8 |
| Access point | Access point rated for the dock's temperature and dust | No model named | 2 |
Also needed, not priced: 11 × cat6 cable run. Cable lengths are not part of the design.
Checks
What the Network Builder's rules found when they compared every part with the others. Each result says what it is based on: the maker's documentation, a standard, a RouterHaus calculation or an estimate. We have not tested this equipment.
Ports, cables and link rates
Unverified Link rate between the internet connection and Firewall or gateway (Office and equipment room) is not known
No speed is published for Firewall or gateway port, so the rate of the link between the internet connection and Firewall or gateway (Office and equipment room) cannot be worked out. Confirm the port speed on the maker's datasheet.
OK 1 wired link rated
Wired links: 1 at 1 Gbps. Each is the slower of its two ports, capped by the cable where a type and length were given. These are Ethernet link rates, not throughput: real transfers are lower and depend on the devices at each end.
Unverified Firewall or gateway (Office and equipment room): WAN port speed not published
No speed is published for Firewall or gateway (Office and equipment room)'s WAN port, so we cannot say whether it carries the 500 Mbps Internet plan. Confirm the port speed on the maker's datasheet.
Power and PoE
Unverified PoE access switch, 24 ports, 802.3at (Office and equipment room): PoE budget not published
No PoE budget is published for PoE access switch, 24 ports, 802.3at (Office and equipment room). This design allocates 8 x High-ceiling access point with directional or narrow-beam antennas (Warehouse floor (high ceiling)) at 30 W (802.3at) and 2 x Access point rated for the dock's temperature and dust (Loading dock) at 30 W (802.3at), 300 W in total. Confirm the budget on the maker's datasheet before relying on it.
Unverified High-ceiling access point with directional or narrow-beam antennas (Warehouse floor (high ceiling)): power draw not published
No maximum power draw is published for High-ceiling access point with directional or narrow-beam antennas (Warehouse floor (high ceiling)). It is allocated 30 W as an 802.3at device, but without the draw figure we cannot confirm that class is enough. Check the maker's datasheet.
Unverified Access point rated for the dock's temperature and dust (Loading dock): power draw not published
No maximum power draw is published for Access point rated for the dock's temperature and dust (Loading dock). It is allocated 30 W as an 802.3at device, but without the draw figure we cannot confirm that class is enough. Check the maker's datasheet.
Management
Unverified Firewall or gateway (Office and equipment room): VLAN support not documented
This design asks for VLANs. No model is chosen for Firewall or gateway (Office and equipment room), so separate networks cannot be confirmed on it.
Catalog data
Note No listed price for 4 parts
No price from the maker's own store or price list is on record for: 1 x Firewall or gateway (no model chosen), 1 x PoE access switch, 24 ports, 802.3at (no model chosen), 8 x High-ceiling access point with directional or narrow-beam antennas (no model chosen) and 2 x Access point rated for the dock's temperature and dust (no model chosen). The parts total leaves them out, so it is a lower bound, not the full cost. We do not fill gaps with retailer prices.
Unverified Firewall or gateway (Office and equipment room): no model chosen
Firewall or gateway (Office and equipment room) is a role without a model. The checks use what was entered for it (5 ports), which is a requirement, not a maker's published specification. Not known: model, price, port speeds and management features. Choose a model to verify this part.
Unverified PoE access switch, 24 ports, 802.3at (Office and equipment room): no model chosen
PoE access switch, 24 ports, 802.3at (Office and equipment room) is a role without a model. The checks use what was entered for it (28 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.
Unverified High-ceiling access point with directional or narrow-beam antennas (Warehouse floor (high ceiling)): no model chosen
High-ceiling access point with directional or narrow-beam antennas (Warehouse floor (high ceiling)) is a role without a model. The checks use what was entered for it (PoE input), which is a requirement, not a maker's published specification. Not known: model, price, ports and management features. Choose a model to verify this part.
Unverified Access point rated for the dock's temperature and dust (Loading dock): no model chosen
Access point rated for the dock's temperature and dust (Loading dock) is a role without a model. The checks use what was entered for it (PoE input), which is a requirement, not a maker's published specification. Not known: model, price, ports and management features. Choose a model to verify this part.
Installation
- Access points mounted at the height and angle the survey specifies, often below the roof structure and above aisles.
- Long runs may need a second closet or fiber to stay within 100 m copper limits.
- Lifts or scissor lifts for mounting; plan safety and access.
Security and segmentation
- Staff (suggested VLAN 10): office computers.
- Devices (suggested VLAN 40): scanners, printers and warehouse systems, reachable only from the systems that manage them.
- Guest (suggested VLAN 30): drivers and visitors, internet only.
| VLAN | Name | Purpose |
|---|---|---|
| staff | Staff | Company laptops and desks |
| devices | Devices | Printers and shared devices; reachable from Staff |
| guest | Guest | Visitors; internet only |
Upgrade paths
- A second switch closet with fiber uplinks for the far end of the building.
- Outdoor yard coverage after checking 6 GHz outdoor rules.
Risks and limits
- Conceptual: the access points and switch are roles; RF coverage among racking needs an on-site survey.
- Inventory changes (full or empty racks) change coverage.
- Cable lengths across a large floor are not checked.
Sources
Maker documents and standards this design was drawn from:
Cited by the checks:
Next steps
Make it yours
Open the design in the builder, change the space, the internet plan or any part, and the checks and total update.
More business designs
Questions that decide the architecture, the tools and the equipment for this kind of site.
Expert help
Request a consultation and paste the builder link into the notes, so the review starts from this design.