Enterprise reference design

Enterprise office

A conceptual reference for a multi-floor headquarters: a high-availability firewall pair on two internet connections, a redundant layer 3 core, stacked PoE access switches per floor on fiber, controller-managed Wi-Fi 7 access points and 802.1X network access control. Every part is a role with requirements; enterprise equipment in this class is quote-only.

Conceptual reference architecture, not a validated design. It names roles and requirements, not validated models, and carries no total price.

Engine result
Conceptual
Parts
No total conceptual design
Wi-Fi units
48 in this design; rule of thumb for the stated space: 8 (an estimate)
Slowest wired link
10 Gbps link rate, not throughput
PoE allocated
2880 W IEEE class allocations
Checks
41 1 OK, 9 notes, 3 need equipment, 28 unverified, 0 incompatible

The builder link carries the whole design in the part of the address after "#", which your browser does not send to our server. A shorter link loads this design by name: www.routerhaus.com/build#design=enterprise-office.

Assumptions

The design was drawn for these inputs. They are assumptions about a typical site, not facts about yours; change them in the builder and every check runs again.

  • Assumption: about 60,000 sq ft over four floors, one closet per floor.
  • Assumption: about 400 wired and 800 Wi-Fi devices.
  • Assumption: two diverse 10 Gbps internet connections with SFP+ handoffs.
  • Assumption: an existing multimode fiber riser between closets.

Internet: Internet A 10 Gbps down, 10 Gbps up (primary); Internet B 10 Gbps down, 10 Gbps up (failover).

Diagram

Each line is labelled with its link rate (the slower of its two ports), the cable and any PoE allocation. A marker and a letter flag a link or device that needs attention; colour is never the only sign.

Enterprise office: network diagramNetwork diagram: 2 internet connections, 13 devices. Check result: Unverified: needs confirmation. Each device lists how it is powered and its link upstream; link rates are Ethernet link rates, not throughput.Internet A 10 Gbps down / 10 Gbps up Firewall A of a high-availability pair, Main equipment roomFirewall A of a high-ava… Main equipment room ? Core switch (one of a redundant pair), layer 3, Main equipment roomCore switch (one of a re… Main equipment room ? Floor 1 access switch stack, 802.3bt PoE, Floor 1 closetFloor 1 access switch st… Floor 1 closet ? 12 x Enterprise Wi-Fi 7 access point, Floor 1 closet12 x Enterprise Wi-Fi 7… Floor 1 closet ? Floor 2 access switch stack, 802.3bt PoE, Floor 2 closetFloor 2 access switch st… Floor 2 closet ? 12 x Enterprise Wi-Fi 7 access point, Floor 2 closet12 x Enterprise Wi-Fi 7… Floor 2 closet ? Floor 3 access switch stack, 802.3bt PoE, Floor 3 closetFloor 3 access switch st… Floor 3 closet ? 12 x Enterprise Wi-Fi 7 access point, Floor 3 closet12 x Enterprise Wi-Fi 7… Floor 3 closet ? Floor 4 access switch stack, 802.3bt PoE, Floor 4 closetFloor 4 access switch st… Floor 4 closet ? 12 x Enterprise Wi-Fi 7 access point, Floor 4 closet12 x Enterprise Wi-Fi 7… Floor 4 closet ? Wireless LAN controller or cloud management, Main equipment roomWireless LAN controller… Main equipment room ? Network access control (802.1X with RADIUS), Main equipment roomNetwork access control (… Main equipment room ? 400 wired devices Counted in the design + Internet B, 10 Gbps down / 10 Gbps up, failoverInternet B 10 Gbps down / 10 Gbps up, fa… Firewall B of a high-availability pair, Main equipment roomFirewall B of a high-ava… Main equipment room ? 800 Wi-Fi devices Counted in the design +
Enterprise office: network diagramNetwork diagram: 2 internet connections, 13 devices. Check result: Unverified: needs confirmation. Each device lists how it is powered and its link upstream; link rates are Ethernet link rates, not throughput.Internet A 10 Gbps down / 10 Gbps up Firewall A of a high-availability pair, Main equipment roomFirewall A of a high-ava… Main equipment room ? Core switch (one of a redundant pair), layer 3, Main equipment roomCore switch (one of a re… Main equipment room ? Floor 1 access switch stack, 802.3bt PoE, Floor 1 closetFloor 1 access switch st… Floor 1 closet ? 12 x Enterprise Wi-Fi 7 access point, Floor 1 closet12 x Enterprise Wi-Fi… Floor 1 closet ? Floor 2 access switch stack, 802.3bt PoE, Floor 2 closetFloor 2 access switch st… Floor 2 closet ? 12 x Enterprise Wi-Fi 7 access point, Floor 2 closet12 x Enterprise Wi-Fi… Floor 2 closet ? Floor 3 access switch stack, 802.3bt PoE, Floor 3 closetFloor 3 access switch st… Floor 3 closet ? 12 x Enterprise Wi-Fi 7 access point, Floor 3 closet12 x Enterprise Wi-Fi… Floor 3 closet ? Floor 4 access switch stack, 802.3bt PoE, Floor 4 closetFloor 4 access switch st… Floor 4 closet ? 12 x Enterprise Wi-Fi 7 access point, Floor 4 closet12 x Enterprise Wi-Fi… Floor 4 closet ? Wireless LAN controller or cloud management, Main equipment roomWireless LAN controller… Main equipment room ? Network access control (802.1X with RADIUS), Main equipment roomNetwork access control (… Main equipment room ? 400 wired devices Counted in the design + Internet B, 10 Gbps down / 10 Gbps up, failoverInternet B 10 Gbps down / 10 Gbps up, fa… Firewall B of a high-availability pair, Main equipment roomFirewall B of a high-ava… Main equipment room ? 800 Wi-Fi devices Counted in the design +
Enterprise office: devices by location, with link rates. A text version follows.
Text version of the diagram
  1. Headquarters
    1. Main equipment room
      1. Internet A, internet connection, 10 Gbps down / 10 Gbps up, connects to Firewall A of a high-availability pair
        1. Firewall A of a high-availability pair, Main equipment room, power not stated, 10 Gbps link to Internet A, status: Unverified: needs confirmation
          1. Core switch (one of a redundant pair), layer 3, Main equipment room, power not stated, 10 Gbps link over SFP+ direct-attach cable to Firewall A of a high-availability pair, status: Unverified: needs confirmation
            1. Floor 1 access switch stack, 802.3bt PoE, Floor 1 closet, power not stated, 10 Gbps link over multimode fiber to Core switch (one of a redundant pair), layer 3, status: Unverified: needs confirmation
              1. 12 x Enterprise Wi-Fi 7 access point, Floor 1 closet, powered by PoE++ from Floor 1 access switch stack, 802.3bt PoE, speed not known links, status: Unverified: needs confirmation
            2. Floor 2 access switch stack, 802.3bt PoE, Floor 2 closet, power not stated, 10 Gbps link over multimode fiber to Core switch (one of a redundant pair), layer 3, status: Unverified: needs confirmation
              1. 12 x Enterprise Wi-Fi 7 access point, Floor 2 closet, powered by PoE++ from Floor 2 access switch stack, 802.3bt PoE, speed not known links, status: Unverified: needs confirmation
            3. Floor 3 access switch stack, 802.3bt PoE, Floor 3 closet, power not stated, 10 Gbps link over multimode fiber to Core switch (one of a redundant pair), layer 3, status: Unverified: needs confirmation
              1. 12 x Enterprise Wi-Fi 7 access point, Floor 3 closet, powered by PoE++ from Floor 3 access switch stack, 802.3bt PoE, speed not known links, status: Unverified: needs confirmation
            4. Floor 4 access switch stack, 802.3bt PoE, Floor 4 closet, power not stated, 10 Gbps link over multimode fiber to Core switch (one of a redundant pair), layer 3, status: Unverified: needs confirmation
              1. 12 x Enterprise Wi-Fi 7 access point, Floor 4 closet, powered by PoE++ from Floor 4 access switch stack, 802.3bt PoE, speed not known links, status: Unverified: needs confirmation
            5. Wireless LAN controller or cloud management, Main equipment room, power not stated, speed not known link over Cat6 to Core switch (one of a redundant pair), layer 3, status: Unverified: needs confirmation
            6. Network access control (802.1X with RADIUS), Main equipment room, power not stated, speed not known link over Cat6 to Core switch (one of a redundant pair), layer 3, status: Unverified: needs confirmation
            7. 400 wired devices, counted in the design, plug into 4 switches, status: Compatible with additional equipment
      2. Internet B, internet connection, 10 Gbps down / 10 Gbps up, failover, connects to Firewall B of a high-availability pair
        1. Firewall B of a high-availability pair, Main equipment room, power not stated, 10 Gbps link to Internet B, status: Unverified: needs confirmation
  2. No site given
    1. Location not given
      1. 800 Wi-Fi devices, counted in the design, no Wi-Fi device in the design to connect to

Connections

Connections in the Enterprise office design
FromToCableLink ratePowerResult
Internet AFirewall A of a high-availability pairSFP+ handoff10 Gbps portNoneCompatible
Firewall A of a high-availability pairCore switch (one of a redundant pair), layer 3SFP+ direct-attach cable10 GbpsNoneCompatible
Core switch (one of a redundant pair), layer 3Floor 1 access switch stack, 802.3bt PoEmultimode fiber10 GbpsNoneCompatible
Core switch (one of a redundant pair), layer 3Floor 2 access switch stack, 802.3bt PoEmultimode fiber10 GbpsNoneCompatible
Core switch (one of a redundant pair), layer 3Floor 3 access switch stack, 802.3bt PoEmultimode fiber10 GbpsNoneCompatible
Core switch (one of a redundant pair), layer 3Floor 4 access switch stack, 802.3bt PoEmultimode fiber10 GbpsNoneCompatible
Core switch (one of a redundant pair), layer 3Wireless LAN controller or cloud managementCat6Not knownNoneCompatible with additional equipment
Core switch (one of a redundant pair), layer 3Network access control (802.1X with RADIUS)Cat6Not knownNoneCompatible with additional equipment
Floor 1 access switch stack, 802.3bt PoE12 x Enterprise Wi-Fi 7 access pointCat612 x speed not knownPoE++ (802.3bt), 720 W allocated (12 x 60 W)Unverified: needs confirmation
Floor 2 access switch stack, 802.3bt PoE12 x Enterprise Wi-Fi 7 access pointCat612 x speed not knownPoE++ (802.3bt), 720 W allocated (12 x 60 W)Unverified: needs confirmation
Floor 3 access switch stack, 802.3bt PoE12 x Enterprise Wi-Fi 7 access pointCat612 x speed not knownPoE++ (802.3bt), 720 W allocated (12 x 60 W)Unverified: needs confirmation
Floor 4 access switch stack, 802.3bt PoE12 x Enterprise Wi-Fi 7 access pointCat612 x speed not knownPoE++ (802.3bt), 720 W allocated (12 x 60 W)Unverified: needs confirmation
Internet BFirewall B of a high-availability pairSFP+ handoff10 Gbps portNoneCompatible
Floor 1 access switch stack, 802.3bt PoE400 wired devicesEthernetNot ratedNoneCompatible
Floor 2 access switch stack, 802.3bt PoE400 wired devicesEthernetNot ratedNoneCompatible
Floor 3 access switch stack, 802.3bt PoE400 wired devicesEthernetNot ratedNoneCompatible
Floor 4 access switch stack, 802.3bt PoE400 wired devicesEthernetNot ratedNoneCompatible

Roles and requirements

Conceptual reference architecture, not a validated design. A role without a model states what the part must do; where the design names a catalogued model, it is an example that meets the role, not a recommendation.

Roles in the Enterprise office design
RoleRequirementExample modelQty
FirewallFirewall A of a high-availability pairNo model named1
FirewallFirewall B of a high-availability pairNo model named1
SwitchCore switch (one of a redundant pair), layer 3No model named1
SwitchFloor 1 access switch stack, 802.3bt PoENo model named1
SwitchFloor 2 access switch stack, 802.3bt PoENo model named1
SwitchFloor 3 access switch stack, 802.3bt PoENo model named1
SwitchFloor 4 access switch stack, 802.3bt PoENo model named1
Access pointEnterprise Wi-Fi 7 access pointNo model named12
Access pointEnterprise Wi-Fi 7 access pointNo model named12
Access pointEnterprise Wi-Fi 7 access pointNo model named12
Access pointEnterprise Wi-Fi 7 access pointNo model named12
ControllerWireless LAN controller or cloud managementNo model named1
ServerNetwork access control (802.1X with RADIUS)No model named1

Also needed, not priced: 1 × sfp+ direct-attach cable; 4 × multimode fiber cable run; 50 × cat6 cable run. Cable lengths are not part of the design.

Checks

What the Network Builder's rules found when they compared every part with the others. Each result says what it is based on: the maker's documentation, a standard, a RouterHaus calculation or an estimate. We have not tested this equipment.

Ports, cables and link rates

  • OK 5 wired links rated

    Wired links: 5 at 10 Gbps. Each is the slower of its two ports, capped by the cable where a type and length were given. These are Ethernet link rates, not throughput: real transfers are lower and depend on the devices at each end.

    Basis: RouterHaus calculation. Source: ieee802.org

  • Note Core switch (one of a redundant pair), layer 3 (Main equipment room) to Floor 1 access switch stack, 802.3bt PoE (Floor 1 closet): 2 10GBASE-SR multimode SFP+ modules listed

    This link is multimode fiber, and Core switch (one of a redundant pair), layer 3 (Main equipment room) uses its 10 Gbps SFP+ port and Floor 1 access switch stack, 802.3bt PoE (Floor 1 closet) uses its 10 Gbps SFP+ port: an SFP+ cage needs an optical module for multimode fiber. It needs 2 10GBASE-SR multimode SFP+ modules per link (one at Core switch (one of a redundant pair), layer 3 (Main equipment room) and one at Floor 1 access switch stack, 802.3bt PoE (Floor 1 closet)), and the design lists them on the link, so they are in the parts list. Check that the module is on the maker's compatibility list for the port.

    Basis: Requirement stated in the design (no model chosen)

  • Note Core switch (one of a redundant pair), layer 3 (Main equipment room) to Floor 2 access switch stack, 802.3bt PoE (Floor 2 closet): 2 10GBASE-SR multimode SFP+ modules listed

    This link is multimode fiber, and Core switch (one of a redundant pair), layer 3 (Main equipment room) uses its 10 Gbps SFP+ port and Floor 2 access switch stack, 802.3bt PoE (Floor 2 closet) uses its 10 Gbps SFP+ port: an SFP+ cage needs an optical module for multimode fiber. It needs 2 10GBASE-SR multimode SFP+ modules per link (one at Core switch (one of a redundant pair), layer 3 (Main equipment room) and one at Floor 2 access switch stack, 802.3bt PoE (Floor 2 closet)), and the design lists them on the link, so they are in the parts list. Check that the module is on the maker's compatibility list for the port.

    Basis: Requirement stated in the design (no model chosen)

  • Note Core switch (one of a redundant pair), layer 3 (Main equipment room) to Floor 3 access switch stack, 802.3bt PoE (Floor 3 closet): 2 10GBASE-SR multimode SFP+ modules listed

    This link is multimode fiber, and Core switch (one of a redundant pair), layer 3 (Main equipment room) uses its 10 Gbps SFP+ port and Floor 3 access switch stack, 802.3bt PoE (Floor 3 closet) uses its 10 Gbps SFP+ port: an SFP+ cage needs an optical module for multimode fiber. It needs 2 10GBASE-SR multimode SFP+ modules per link (one at Core switch (one of a redundant pair), layer 3 (Main equipment room) and one at Floor 3 access switch stack, 802.3bt PoE (Floor 3 closet)), and the design lists them on the link, so they are in the parts list. Check that the module is on the maker's compatibility list for the port.

    Basis: Requirement stated in the design (no model chosen)

  • Note Core switch (one of a redundant pair), layer 3 (Main equipment room) to Floor 4 access switch stack, 802.3bt PoE (Floor 4 closet): 2 10GBASE-SR multimode SFP+ modules listed

    This link is multimode fiber, and Core switch (one of a redundant pair), layer 3 (Main equipment room) uses its 10 Gbps SFP+ port and Floor 4 access switch stack, 802.3bt PoE (Floor 4 closet) uses its 10 Gbps SFP+ port: an SFP+ cage needs an optical module for multimode fiber. It needs 2 10GBASE-SR multimode SFP+ modules per link (one at Core switch (one of a redundant pair), layer 3 (Main equipment room) and one at Floor 4 access switch stack, 802.3bt PoE (Floor 4 closet)), and the design lists them on the link, so they are in the parts list. Check that the module is on the maker's compatibility list for the port.

    Basis: Requirement stated in the design (no model chosen)

  • Needs equipment Core switch (one of a redundant pair), layer 3 (Main equipment room) to Wireless LAN controller or cloud management (Main equipment room): needs 1 10GBASE-T copper SFP+ module

    This link is Cat6, and Core switch (one of a redundant pair), layer 3 (Main equipment room) uses its 10 Gbps SFP+ port: Cat6 does not plug into an SFP+ cage. It needs 1 10GBASE-T copper SFP+ module per link (one at Core switch (one of a redundant pair), layer 3 (Main equipment room)); none is listed. Check that the module is on the maker's compatibility list for the port.

    Basis: Requirement stated in the design (no model chosen). Fix: Add 1 10GBASE-T copper SFP+ module

  • Needs equipment Core switch (one of a redundant pair), layer 3 (Main equipment room) to Network access control (802.1X with RADIUS) (Main equipment room): needs 1 10GBASE-T copper SFP+ module

    This link is Cat6, and Core switch (one of a redundant pair), layer 3 (Main equipment room) uses its 10 Gbps SFP+ port: Cat6 does not plug into an SFP+ cage. It needs 1 10GBASE-T copper SFP+ module per link (one at Core switch (one of a redundant pair), layer 3 (Main equipment room)); none is listed. Check that the module is on the maker's compatibility list for the port.

    Basis: Requirement stated in the design (no model chosen). Fix: Add 1 10GBASE-T copper SFP+ module

  • Note Internet A: the WAN port carries the plan

    Firewall A of a high-availability pair (Main equipment room)'s 10 Gbps WAN port is at or above the 10 Gbps Internet A plan. This compares port speed with plan speed; it is not a throughput test.

    Basis: Requirement stated in the design (no model chosen)

  • Note Internet B: the WAN port carries the plan

    Firewall B of a high-availability pair (Main equipment room)'s 10 Gbps WAN port is at or above the 10 Gbps Internet B plan. This compares port speed with plan speed; it is not a throughput test.

    Basis: Requirement stated in the design (no model chosen)

Power and PoE

  • Unverified Floor 1 access switch stack, 802.3bt PoE (Floor 1 closet): PoE budget not published

    No PoE budget is published for Floor 1 access switch stack, 802.3bt PoE (Floor 1 closet). This design allocates 12 x Enterprise Wi-Fi 7 access point (Floor 1 closet) at 60 W (802.3bt), 720 W in total. Confirm the budget on the maker's datasheet before relying on it.

    Basis: RouterHaus calculation. Source: ieee802.org

  • Unverified Floor 2 access switch stack, 802.3bt PoE (Floor 2 closet): PoE budget not published

    No PoE budget is published for Floor 2 access switch stack, 802.3bt PoE (Floor 2 closet). This design allocates 12 x Enterprise Wi-Fi 7 access point (Floor 2 closet) at 60 W (802.3bt), 720 W in total. Confirm the budget on the maker's datasheet before relying on it.

    Basis: RouterHaus calculation. Source: ieee802.org

  • Unverified Floor 3 access switch stack, 802.3bt PoE (Floor 3 closet): PoE budget not published

    No PoE budget is published for Floor 3 access switch stack, 802.3bt PoE (Floor 3 closet). This design allocates 12 x Enterprise Wi-Fi 7 access point (Floor 3 closet) at 60 W (802.3bt), 720 W in total. Confirm the budget on the maker's datasheet before relying on it.

    Basis: RouterHaus calculation. Source: ieee802.org

  • Unverified Floor 4 access switch stack, 802.3bt PoE (Floor 4 closet): PoE budget not published

    No PoE budget is published for Floor 4 access switch stack, 802.3bt PoE (Floor 4 closet). This design allocates 12 x Enterprise Wi-Fi 7 access point (Floor 4 closet) at 60 W (802.3bt), 720 W in total. Confirm the budget on the maker's datasheet before relying on it.

    Basis: RouterHaus calculation. Source: ieee802.org

  • Unverified Enterprise Wi-Fi 7 access point (Floor 1 closet): power draw not published

    No maximum power draw is published for Enterprise Wi-Fi 7 access point (Floor 1 closet). It is allocated 60 W as an 802.3bt device, but without the draw figure we cannot confirm that class is enough. Check the maker's datasheet.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Enterprise Wi-Fi 7 access point (Floor 2 closet): power draw not published

    No maximum power draw is published for Enterprise Wi-Fi 7 access point (Floor 2 closet). It is allocated 60 W as an 802.3bt device, but without the draw figure we cannot confirm that class is enough. Check the maker's datasheet.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Enterprise Wi-Fi 7 access point (Floor 3 closet): power draw not published

    No maximum power draw is published for Enterprise Wi-Fi 7 access point (Floor 3 closet). It is allocated 60 W as an 802.3bt device, but without the draw figure we cannot confirm that class is enough. Check the maker's datasheet.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Enterprise Wi-Fi 7 access point (Floor 4 closet): power draw not published

    No maximum power draw is published for Enterprise Wi-Fi 7 access point (Floor 4 closet). It is allocated 60 W as an 802.3bt device, but without the draw figure we cannot confirm that class is enough. Check the maker's datasheet.

    Basis: Requirement stated in the design (no model chosen)

Management

  • Unverified Firewall A of a high-availability pair (Main equipment room): VLAN support not documented

    This design asks for VLANs and a guest network. No model is chosen for Firewall A of a high-availability pair (Main equipment room), so separate networks cannot be confirmed on it.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Firewall B of a high-availability pair (Main equipment room): VLAN support not documented

    This design asks for VLANs and a guest network. No model is chosen for Firewall B of a high-availability pair (Main equipment room), so separate networks cannot be confirmed on it.

    Basis: Requirement stated in the design (no model chosen)

  • Note Multi-gig wired port: 10 Gbps on Firewall A of a high-availability pair (Main equipment room)

    The fastest port for a wired device is 10 Gbps on Firewall A of a high-availability pair (Main equipment room). Whether one is still free depends on what else is connected to it.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Firewall A of a high-availability pair (Main equipment room): VPN server not confirmed

    This design asks for a VPN server. No model is chosen for Firewall A of a high-availability pair (Main equipment room), so it cannot be confirmed.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Firewall A of a high-availability pair (Main equipment room): IDS/IPS not confirmed

    This design asks for IDS/IPS. No model is chosen for Firewall A of a high-availability pair (Main equipment room), so we cannot say whether it has threat inspection or how fast it is with it on.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Firewall B of a high-availability pair (Main equipment room): VPN server not confirmed

    This design asks for a VPN server. No model is chosen for Firewall B of a high-availability pair (Main equipment room), so it cannot be confirmed.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Firewall B of a high-availability pair (Main equipment room): IDS/IPS not confirmed

    This design asks for IDS/IPS. No model is chosen for Firewall B of a high-availability pair (Main equipment room), so we cannot say whether it has threat inspection or how fast it is with it on.

    Basis: Requirement stated in the design (no model chosen)

Resilience

  • Unverified 2 gateways at Headquarters: HA pairing not confirmed

    This design has 2 gateways at Headquarters (Firewall A of a high-availability pair and Firewall B of a high-availability pair). Whether these models can run as a redundant pair, and how failover between them works, is not in our records. Confirm it in the maker's documentation.

    Basis: Requirement stated in the design (no model chosen)

  • Note Core switch (one of a redundant pair), layer 3 (Main equipment room): 4:1 downstream to uplink

    Core switch (one of a redundant pair), layer 3 (Main equipment room) has 4 downstream links adding up to 40 Gbps of link rate and a 10 Gbps uplink: 4 to 1. That is normal for access switches, since devices rarely all send at once; it matters when several fast devices behind it talk to the rest of the network at the same time. This is arithmetic on link rates, not a traffic forecast.

    Basis: RouterHaus calculation

  • Needs equipment 64 wired devices without a port

    The design counts 400 wired devices. After every connection in it is made, 336 RJ45 ports are free on its gateways and switches, so 64 have nowhere to plug in. Add switch ports: at least 64, plus one per added switch for its uplink.

    Basis: RouterHaus calculation. Fix: Add at least 64 switch ports

Catalog data

  • Note No listed price for 12 parts

    No price from the maker's own store or price list is on record for: 1 x Firewall A of a high-availability pair (no model chosen), 1 x Firewall B of a high-availability pair (no model chosen), 1 x Core switch (one of a redundant pair), layer 3 (no model chosen), 1 x Floor 1 access switch stack, 802.3bt PoE (no model chosen), 1 x Floor 2 access switch stack, 802.3bt PoE (no model chosen), 1 x Floor 3 access switch stack, 802.3bt PoE (no model chosen), 1 x Floor 4 access switch stack, 802.3bt PoE (no model chosen), 48 x Enterprise Wi-Fi 7 access point (no model chosen), 1 x Wireless LAN controller or cloud management (no model chosen), 1 x Network access control (802.1X with RADIUS) (no model chosen), 8 x 10GBASE-SR multimode SFP+ module and 2 x 10GBASE-T copper SFP+ module. The parts total leaves them out, so it is a lower bound, not the full cost. We do not fill gaps with retailer prices.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Firewall A of a high-availability pair (Main equipment room): no model chosen

    Firewall A of a high-availability pair (Main equipment room) is a role without a model. The checks use what was entered for it (6 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Firewall B of a high-availability pair (Main equipment room): no model chosen

    Firewall B of a high-availability pair (Main equipment room) is a role without a model. The checks use what was entered for it (6 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Core switch (one of a redundant pair), layer 3 (Main equipment room): no model chosen

    Core switch (one of a redundant pair), layer 3 (Main equipment room) is a role without a model. The checks use what was entered for it (32 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Floor 1 access switch stack, 802.3bt PoE (Floor 1 closet): no model chosen

    Floor 1 access switch stack, 802.3bt PoE (Floor 1 closet) is a role without a model. The checks use what was entered for it (100 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Floor 2 access switch stack, 802.3bt PoE (Floor 2 closet): no model chosen

    Floor 2 access switch stack, 802.3bt PoE (Floor 2 closet) is a role without a model. The checks use what was entered for it (100 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Floor 3 access switch stack, 802.3bt PoE (Floor 3 closet): no model chosen

    Floor 3 access switch stack, 802.3bt PoE (Floor 3 closet) is a role without a model. The checks use what was entered for it (100 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Floor 4 access switch stack, 802.3bt PoE (Floor 4 closet): no model chosen

    Floor 4 access switch stack, 802.3bt PoE (Floor 4 closet) is a role without a model. The checks use what was entered for it (100 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Enterprise Wi-Fi 7 access point (Floor 1 closet): no model chosen

    Enterprise Wi-Fi 7 access point (Floor 1 closet) is a role without a model. The checks use what was entered for it (PoE input), which is a requirement, not a maker's published specification. Not known: model, price, ports and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Enterprise Wi-Fi 7 access point (Floor 2 closet): no model chosen

    Enterprise Wi-Fi 7 access point (Floor 2 closet) is a role without a model. The checks use what was entered for it (PoE input), which is a requirement, not a maker's published specification. Not known: model, price, ports and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Enterprise Wi-Fi 7 access point (Floor 3 closet): no model chosen

    Enterprise Wi-Fi 7 access point (Floor 3 closet) is a role without a model. The checks use what was entered for it (PoE input), which is a requirement, not a maker's published specification. Not known: model, price, ports and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Enterprise Wi-Fi 7 access point (Floor 4 closet): no model chosen

    Enterprise Wi-Fi 7 access point (Floor 4 closet) is a role without a model. The checks use what was entered for it (PoE input), which is a requirement, not a maker's published specification. Not known: model, price, ports and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Wireless LAN controller or cloud management (Main equipment room): no model chosen

    Wireless LAN controller or cloud management (Main equipment room) is a role without a model. Nothing was entered for its ports or power, so its links were not checked; what was entered is a requirement, not a maker's published specification. Not known: model, price, ports and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

  • Unverified Network access control (802.1X with RADIUS) (Main equipment room): no model chosen

    Network access control (802.1X with RADIUS) (Main equipment room) is a role without a model. Nothing was entered for its ports or power, so its links were not checked; what was entered is a requirement, not a maker's published specification. Not known: model, price, ports and management features. Choose a model to verify this part.

    Basis: Requirement stated in the design (no model chosen)

Installation

  • Main equipment room with redundant power feeds, UPS and cooling sized by the facilities team.
  • Each closet: stacked access switches with two fiber uplinks to the core pair.
  • Access-point placement and count from a predictive design checked by an on-site survey.

Security and segmentation

  • Staff, Guest, Devices, Voice and Management VLANs; 802.1X assigns staff devices to their VLAN.
  • Guest traffic tunneled or routed straight to the internet.
  • Management networks reachable only from a jump host or administrator VLAN.
  • Firewall policy between internal segments, not only at the internet edge.
Networks in the Enterprise office design
VLANNamePurpose
staffStaffCompany laptops and desks
guestGuestVisitors; internet only
devicesDevicesPrinters and shared devices; reachable from Staff
voiceVoiceDesk phones
mgmtManagementSwitch, access point and controller management

Upgrade paths

  • Segment further by department or application as policy requires.
  • Add a second site and SD-WAN between sites (see the campus and multi-location templates).

Risks and limits

  • Conceptual reference architecture, not a validated design: no model, port count, power budget or price is checked.
  • Any licences or support contracts the chosen equipment needs are not priced here: ask the makers you shortlist.
  • RF design needs a professional survey.

Sources

Maker documents and standards this design was drawn from:

Cited by the checks:

Design data updated . Prices and specifications come from the RouterHaus catalog; see how we work.

Next steps

Make it yours

Open the design in the builder, change the space, the internet plan or any part, and the checks and total update.

Open in the builder

More enterprise designs

Questions that decide the architecture, the tools and the equipment for this kind of site.

Enterprise solutions · All designs

Expert help

Request a consultation and paste the builder link into the notes, so the review starts from this design.

Request a review

Related guides

Your privacy choices

RouterHaus uses Google Analytics to understand which pages help people. We don't sell personal information. Advertising cookies are off.

Until you save a choice here, analytics cookies are off for visitors in the EEA, UK and Switzerland and in browsers that send Global Privacy Control; elsewhere they're on. When they're off, Google may still receive cookieless pings without identifiers. A choice you save here applies in this browser wherever you are, and your analytics choice applies even if the browser sends Global Privacy Control.