Enterprise reference design
Campus backbone
A conceptual backbone for several buildings: an edge firewall pair, a redundant campus core, a layer 3 distribution switch per building on single-mode fiber, and access switches below each. Access points hang off the access switches and are sized per building by a site survey, so they are not drawn here. Every part is a role; the point is the layering, the fiber links and where routing and policy happen.
Conceptual reference architecture, not a validated design. It names roles and requirements, not validated models, and carries no total price.
- Engine result
- Conceptual
- Parts
- No total conceptual design
- Wi-Fi units
- None this design has no access points
- Slowest wired link
- 10 Gbps link rate, not throughput
- PoE allocated
- 0 W IEEE class allocations
- Checks
- 30 1 OK, 10 notes, 3 need equipment, 16 unverified, 0 incompatible
The builder link carries the whole design in the part of the address after "#", which your browser does not send to our server. A shorter link loads this design by name: www.routerhaus.com/build#design=campus-backbone.
Assumptions
The design was drawn for these inputs. They are assumptions about a typical site, not facts about yours; change them in the builder and every check runs again.
- Assumption: three buildings, each with a distribution room, linked to a campus data room by single-mode fiber.
- Assumption: about 1,000 wired and 2,000 Wi-Fi devices across the campus. The Wi-Fi devices connect through access points that a survey sizes per building; this backbone design does not count them.
- Assumption: two diverse internet connections at the data room.
Diagram
Each line is labelled with its link rate (the slower of its two ports), the cable and any PoE allocation. A marker and a letter flag a link or device that needs attention; colour is never the only sign.
Text version of the diagram
- Campus
- Campus data room, Building A
- Internet A, internet connection, 10 Gbps down / 10 Gbps up, connects to Edge firewall A (high-availability pair)
- Edge firewall A (high-availability pair), Campus data room, Building A, power not stated, 10 Gbps link to Internet A, status: Unverified: needs confirmation
- Campus core switch (one of a redundant pair), layer 3, Campus data room, Building A, power not stated, 10 Gbps link over SFP+ direct-attach cable to Edge firewall A (high-availability pair), status: Unverified: needs confirmation
- Building A distribution switch, layer 3, Building A distribution, Building A, power not stated, 10 Gbps link over single-mode fiber to Campus core switch (one of a redundant pair), layer 3, status: Unverified: needs confirmation
- Building A access switches, PoE, Building A distribution, Building A, power not stated, 10 Gbps link over multimode fiber to Building A distribution switch, layer 3, status: Unverified: needs confirmation
- Building B distribution switch, layer 3, Building B distribution, Building B, power not stated, 10 Gbps link over single-mode fiber to Campus core switch (one of a redundant pair), layer 3, status: Unverified: needs confirmation
- Building B access switches, PoE, Building B distribution, Building B, power not stated, 10 Gbps link over multimode fiber to Building B distribution switch, layer 3, status: Unverified: needs confirmation
- Building C distribution switch, layer 3, Building C distribution, Building C, power not stated, 10 Gbps link over single-mode fiber to Campus core switch (one of a redundant pair), layer 3, status: Unverified: needs confirmation
- Building C access switches, PoE, Building C distribution, Building C, power not stated, 10 Gbps link over multimode fiber to Building C distribution switch, layer 3, status: Unverified: needs confirmation
- Wireless LAN controller or cloud management, Campus data room, Building A, power not stated, speed not known link over Cat6 to Campus core switch (one of a redundant pair), layer 3, status: Unverified: needs confirmation
- Network access control (802.1X with RADIUS), Campus data room, Building A, power not stated, speed not known link over Cat6 to Campus core switch (one of a redundant pair), layer 3, status: Unverified: needs confirmation
- 1000 wired devices, counted in the design, plug into Building A access switches, PoE, Building B access switches, PoE and Building C access switches, PoE, status: Compatible with additional equipment
- Building A distribution switch, layer 3, Building A distribution, Building A, power not stated, 10 Gbps link over single-mode fiber to Campus core switch (one of a redundant pair), layer 3, status: Unverified: needs confirmation
- Campus core switch (one of a redundant pair), layer 3, Campus data room, Building A, power not stated, 10 Gbps link over SFP+ direct-attach cable to Edge firewall A (high-availability pair), status: Unverified: needs confirmation
- Edge firewall A (high-availability pair), Campus data room, Building A, power not stated, 10 Gbps link to Internet A, status: Unverified: needs confirmation
- Internet B, internet connection, 10 Gbps down / 10 Gbps up, failover, connects to Edge firewall B (high-availability pair)
- Edge firewall B (high-availability pair), Campus data room, Building A, power not stated, 10 Gbps link to Internet B, status: Unverified: needs confirmation
- Internet A, internet connection, 10 Gbps down / 10 Gbps up, connects to Edge firewall A (high-availability pair)
- Campus data room, Building A
Connections
| From | To | Cable | Link rate | Power | Result |
|---|---|---|---|---|---|
| Internet A | Edge firewall A (high-availability pair) | SFP+ handoff | 10 Gbps port | None | Compatible |
| Edge firewall A (high-availability pair) | Campus core switch (one of a redundant pair), layer 3 | SFP+ direct-attach cable | 10 Gbps | None | Compatible |
| Campus core switch (one of a redundant pair), layer 3 | Building A distribution switch, layer 3 | single-mode fiber | 10 Gbps | None | Compatible |
| Campus core switch (one of a redundant pair), layer 3 | Building B distribution switch, layer 3 | single-mode fiber | 10 Gbps | None | Compatible |
| Campus core switch (one of a redundant pair), layer 3 | Building C distribution switch, layer 3 | single-mode fiber | 10 Gbps | None | Compatible |
| Campus core switch (one of a redundant pair), layer 3 | Wireless LAN controller or cloud management | Cat6 | Not known | None | Compatible with additional equipment |
| Campus core switch (one of a redundant pair), layer 3 | Network access control (802.1X with RADIUS) | Cat6 | Not known | None | Compatible with additional equipment |
| Building A distribution switch, layer 3 | Building A access switches, PoE | multimode fiber | 10 Gbps | None | Compatible |
| Building B distribution switch, layer 3 | Building B access switches, PoE | multimode fiber | 10 Gbps | None | Compatible |
| Building C distribution switch, layer 3 | Building C access switches, PoE | multimode fiber | 10 Gbps | None | Compatible |
| Internet B | Edge firewall B (high-availability pair) | SFP+ handoff | 10 Gbps port | None | Compatible |
| Building A access switches, PoE | 1000 wired devices | Ethernet | Not rated | None | Compatible |
| Building B access switches, PoE | 1000 wired devices | Ethernet | Not rated | None | Compatible |
| Building C access switches, PoE | 1000 wired devices | Ethernet | Not rated | None | Compatible |
Roles and requirements
Conceptual reference architecture, not a validated design. A role without a model states what the part must do; where the design names a catalogued model, it is an example that meets the role, not a recommendation.
| Role | Requirement | Example model | Qty |
|---|---|---|---|
| Firewall | Edge firewall A (high-availability pair) | No model named | 1 |
| Firewall | Edge firewall B (high-availability pair) | No model named | 1 |
| Switch | Campus core switch (one of a redundant pair), layer 3 | No model named | 1 |
| Switch | Building A distribution switch, layer 3 | No model named | 1 |
| Switch | Building B distribution switch, layer 3 | No model named | 1 |
| Switch | Building C distribution switch, layer 3 | No model named | 1 |
| Switch | Building A access switches, PoE | No model named | 1 |
| Switch | Building B access switches, PoE | No model named | 1 |
| Switch | Building C access switches, PoE | No model named | 1 |
| Controller | Wireless LAN controller or cloud management | No model named | 1 |
| Server | Network access control (802.1X with RADIUS) | No model named | 1 |
Also needed, not priced: 1 × sfp+ direct-attach cable; 3 × single-mode fiber cable run; 3 × multimode fiber cable run; 2 × cat6 cable run. Cable lengths are not part of the design.
Checks
What the Network Builder's rules found when they compared every part with the others. Each result says what it is based on: the maker's documentation, a standard, a RouterHaus calculation or an estimate. We have not tested this equipment.
Ports, cables and link rates
OK 7 wired links rated
Wired links: 7 at 10 Gbps. Each is the slower of its two ports, capped by the cable where a type and length were given. These are Ethernet link rates, not throughput: real transfers are lower and depend on the devices at each end.
Note Campus core switch (one of a redundant pair), layer 3 (Campus data room) to Building A distribution switch, layer 3 (Building A distribution): 2 10GBASE-LR single-mode SFP+ modules listed
This link is single-mode fiber, and Campus core switch (one of a redundant pair), layer 3 (Campus data room) uses its 10 Gbps SFP+ port and Building A distribution switch, layer 3 (Building A distribution) uses its 10 Gbps SFP+ port: an SFP+ cage needs an optical module for single-mode fiber. It needs 2 10GBASE-LR single-mode SFP+ modules per link (one at Campus core switch (one of a redundant pair), layer 3 (Campus data room) and one at Building A distribution switch, layer 3 (Building A distribution)), and the design lists them on the link, so they are in the parts list. Check that the module is on the maker's compatibility list for the port.
Note Campus core switch (one of a redundant pair), layer 3 (Campus data room) to Building B distribution switch, layer 3 (Building B distribution): 2 10GBASE-LR single-mode SFP+ modules listed
This link is single-mode fiber, and Campus core switch (one of a redundant pair), layer 3 (Campus data room) uses its 10 Gbps SFP+ port and Building B distribution switch, layer 3 (Building B distribution) uses its 10 Gbps SFP+ port: an SFP+ cage needs an optical module for single-mode fiber. It needs 2 10GBASE-LR single-mode SFP+ modules per link (one at Campus core switch (one of a redundant pair), layer 3 (Campus data room) and one at Building B distribution switch, layer 3 (Building B distribution)), and the design lists them on the link, so they are in the parts list. Check that the module is on the maker's compatibility list for the port.
Note Campus core switch (one of a redundant pair), layer 3 (Campus data room) to Building C distribution switch, layer 3 (Building C distribution): 2 10GBASE-LR single-mode SFP+ modules listed
This link is single-mode fiber, and Campus core switch (one of a redundant pair), layer 3 (Campus data room) uses its 10 Gbps SFP+ port and Building C distribution switch, layer 3 (Building C distribution) uses its 10 Gbps SFP+ port: an SFP+ cage needs an optical module for single-mode fiber. It needs 2 10GBASE-LR single-mode SFP+ modules per link (one at Campus core switch (one of a redundant pair), layer 3 (Campus data room) and one at Building C distribution switch, layer 3 (Building C distribution)), and the design lists them on the link, so they are in the parts list. Check that the module is on the maker's compatibility list for the port.
Needs equipment Campus core switch (one of a redundant pair), layer 3 (Campus data room) to Wireless LAN controller or cloud management (Campus data room): needs 1 10GBASE-T copper SFP+ module
This link is Cat6, and Campus core switch (one of a redundant pair), layer 3 (Campus data room) uses its 10 Gbps SFP+ port: Cat6 does not plug into an SFP+ cage. It needs 1 10GBASE-T copper SFP+ module per link (one at Campus core switch (one of a redundant pair), layer 3 (Campus data room)); none is listed. Check that the module is on the maker's compatibility list for the port.
Needs equipment Campus core switch (one of a redundant pair), layer 3 (Campus data room) to Network access control (802.1X with RADIUS) (Campus data room): needs 1 10GBASE-T copper SFP+ module
This link is Cat6, and Campus core switch (one of a redundant pair), layer 3 (Campus data room) uses its 10 Gbps SFP+ port: Cat6 does not plug into an SFP+ cage. It needs 1 10GBASE-T copper SFP+ module per link (one at Campus core switch (one of a redundant pair), layer 3 (Campus data room)); none is listed. Check that the module is on the maker's compatibility list for the port.
Note Building A distribution switch, layer 3 (Building A distribution) to Building A access switches, PoE (Building A distribution): 2 10GBASE-SR multimode SFP+ modules listed
This link is multimode fiber, and Building A distribution switch, layer 3 (Building A distribution) uses its 10 Gbps SFP+ port and Building A access switches, PoE (Building A distribution) uses its 10 Gbps SFP+ port: an SFP+ cage needs an optical module for multimode fiber. It needs 2 10GBASE-SR multimode SFP+ modules per link (one at Building A distribution switch, layer 3 (Building A distribution) and one at Building A access switches, PoE (Building A distribution)), and the design lists them on the link, so they are in the parts list. Check that the module is on the maker's compatibility list for the port.
Note Building B distribution switch, layer 3 (Building B distribution) to Building B access switches, PoE (Building B distribution): 2 10GBASE-SR multimode SFP+ modules listed
This link is multimode fiber, and Building B distribution switch, layer 3 (Building B distribution) uses its 10 Gbps SFP+ port and Building B access switches, PoE (Building B distribution) uses its 10 Gbps SFP+ port: an SFP+ cage needs an optical module for multimode fiber. It needs 2 10GBASE-SR multimode SFP+ modules per link (one at Building B distribution switch, layer 3 (Building B distribution) and one at Building B access switches, PoE (Building B distribution)), and the design lists them on the link, so they are in the parts list. Check that the module is on the maker's compatibility list for the port.
Note Building C distribution switch, layer 3 (Building C distribution) to Building C access switches, PoE (Building C distribution): 2 10GBASE-SR multimode SFP+ modules listed
This link is multimode fiber, and Building C distribution switch, layer 3 (Building C distribution) uses its 10 Gbps SFP+ port and Building C access switches, PoE (Building C distribution) uses its 10 Gbps SFP+ port: an SFP+ cage needs an optical module for multimode fiber. It needs 2 10GBASE-SR multimode SFP+ modules per link (one at Building C distribution switch, layer 3 (Building C distribution) and one at Building C access switches, PoE (Building C distribution)), and the design lists them on the link, so they are in the parts list. Check that the module is on the maker's compatibility list for the port.
Note Internet A: the WAN port carries the plan
Edge firewall A (high-availability pair) (Campus data room)'s 10 Gbps WAN port is at or above the 10 Gbps Internet A plan. This compares port speed with plan speed; it is not a throughput test.
Note Internet B: the WAN port carries the plan
Edge firewall B (high-availability pair) (Campus data room)'s 10 Gbps WAN port is at or above the 10 Gbps Internet B plan. This compares port speed with plan speed; it is not a throughput test.
Management
Unverified Edge firewall A (high-availability pair) (Campus data room): VLAN support not documented
This design asks for VLANs and a guest network. No model is chosen for Edge firewall A (high-availability pair) (Campus data room), so separate networks cannot be confirmed on it.
Unverified Edge firewall B (high-availability pair) (Campus data room): VLAN support not documented
This design asks for VLANs and a guest network. No model is chosen for Edge firewall B (high-availability pair) (Campus data room), so separate networks cannot be confirmed on it.
Unverified Edge firewall A (high-availability pair) (Campus data room): IDS/IPS not confirmed
This design asks for IDS/IPS. No model is chosen for Edge firewall A (high-availability pair) (Campus data room), so we cannot say whether it has threat inspection or how fast it is with it on.
Unverified Edge firewall B (high-availability pair) (Campus data room): IDS/IPS not confirmed
This design asks for IDS/IPS. No model is chosen for Edge firewall B (high-availability pair) (Campus data room), so we cannot say whether it has threat inspection or how fast it is with it on.
Resilience
Unverified 2 gateways at Campus: HA pairing not confirmed
This design has 2 gateways at Campus (Edge firewall A (high-availability pair) and Edge firewall B (high-availability pair)). Whether these models can run as a redundant pair, and how failover between them works, is not in our records. Confirm it in the maker's documentation.
Note Campus core switch (one of a redundant pair), layer 3 (Campus data room): 3:1 downstream to uplink
Campus core switch (one of a redundant pair), layer 3 (Campus data room) has 3 downstream links adding up to 30 Gbps of link rate and a 10 Gbps uplink: 3 to 1. That is normal for access switches, since devices rarely all send at once; it matters when several fast devices behind it talk to the rest of the network at the same time. This is arithmetic on link rates, not a traffic forecast.
Needs equipment 856 wired devices without a port
The design counts 1000 wired devices. After every connection in it is made, 144 RJ45 ports are free on its gateways and switches, so 856 have nowhere to plug in. Add switch ports: at least 856, plus one per added switch for its uplink.
Catalog data
Note No listed price for 14 parts
No price from the maker's own store or price list is on record for: 1 x Edge firewall A (high-availability pair) (no model chosen), 1 x Edge firewall B (high-availability pair) (no model chosen), 1 x Campus core switch (one of a redundant pair), layer 3 (no model chosen), 1 x Building A distribution switch, layer 3 (no model chosen), 1 x Building B distribution switch, layer 3 (no model chosen), 1 x Building C distribution switch, layer 3 (no model chosen), 1 x Building A access switches, PoE (no model chosen), 1 x Building B access switches, PoE (no model chosen), 1 x Building C access switches, PoE (no model chosen), 1 x Wireless LAN controller or cloud management (no model chosen), 1 x Network access control (802.1X with RADIUS) (no model chosen), 6 x 10GBASE-LR single-mode SFP+ module, 6 x 10GBASE-SR multimode SFP+ module and 2 x 10GBASE-T copper SFP+ module. The parts total leaves them out, so it is a lower bound, not the full cost. We do not fill gaps with retailer prices.
Unverified Edge firewall A (high-availability pair) (Campus data room): no model chosen
Edge firewall A (high-availability pair) (Campus data room) is a role without a model. The checks use what was entered for it (6 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.
Unverified Edge firewall B (high-availability pair) (Campus data room): no model chosen
Edge firewall B (high-availability pair) (Campus data room) is a role without a model. The checks use what was entered for it (6 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.
Unverified Campus core switch (one of a redundant pair), layer 3 (Campus data room): no model chosen
Campus core switch (one of a redundant pair), layer 3 (Campus data room) is a role without a model. The checks use what was entered for it (48 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.
Unverified Building A distribution switch, layer 3 (Building A distribution): no model chosen
Building A distribution switch, layer 3 (Building A distribution) is a role without a model. The checks use what was entered for it (24 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.
Unverified Building B distribution switch, layer 3 (Building B distribution): no model chosen
Building B distribution switch, layer 3 (Building B distribution) is a role without a model. The checks use what was entered for it (24 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.
Unverified Building C distribution switch, layer 3 (Building C distribution): no model chosen
Building C distribution switch, layer 3 (Building C distribution) is a role without a model. The checks use what was entered for it (24 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.
Unverified Building A access switches, PoE (Building A distribution): no model chosen
Building A access switches, PoE (Building A distribution) is a role without a model. The checks use what was entered for it (52 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.
Unverified Building B access switches, PoE (Building B distribution): no model chosen
Building B access switches, PoE (Building B distribution) is a role without a model. The checks use what was entered for it (52 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.
Unverified Building C access switches, PoE (Building C distribution): no model chosen
Building C access switches, PoE (Building C distribution) is a role without a model. The checks use what was entered for it (52 ports), which is a requirement, not a maker's published specification. Not known: model, price and management features. Choose a model to verify this part.
Unverified Wireless LAN controller or cloud management (Campus data room): no model chosen
Wireless LAN controller or cloud management (Campus data room) is a role without a model. Nothing was entered for its ports or power, so its links were not checked; what was entered is a requirement, not a maker's published specification. Not known: model, price, ports and management features. Choose a model to verify this part.
Unverified Network access control (802.1X with RADIUS) (Campus data room): no model chosen
Network access control (802.1X with RADIUS) (Campus data room) is a role without a model. Nothing was entered for its ports or power, so its links were not checked; what was entered is a requirement, not a maker's published specification. Not known: model, price, ports and management features. Choose a model to verify this part.
Installation
- Single-mode fiber between buildings (10GBASE-LR optics are specified to 10 km); multimode inside buildings.
- Redundant fiber paths between the core and each building where the cable plant allows.
- Each building's distribution room with UPS and cooling.
Security and segmentation
- Routing at the distribution layer with policy between building segments.
- Staff, Guest, Devices, Voice and Management VLANs, numbered the same in every building.
- 802.1X for staff access; guest traffic isolated to the internet edge.
| VLAN | Name | Purpose |
|---|---|---|
| staff | Staff | Company laptops and desks |
| guest | Guest | Visitors; internet only |
| devices | Devices | Printers and shared devices; reachable from Staff |
| voice | Voice | Desk phones |
| mgmt | Management | Switch, access point and controller management |
Upgrade paths
- 25 or 100 Gbps core links as traffic grows.
- A second campus data room for site resilience.
Risks and limits
- Conceptual reference architecture, not a validated design: no model, port, optic budget or price is checked.
- Fiber plant condition and length are not known.
- Quote-only equipment; licensing and support are not priced.
Sources
Maker documents and standards this design was drawn from:
Cited by the checks:
Next steps
Make it yours
Open the design in the builder, change the space, the internet plan or any part, and the checks and total update.
More enterprise designs
Questions that decide the architecture, the tools and the equipment for this kind of site.
Expert help
Request a consultation and paste the builder link into the notes, so the review starts from this design.