The cable in the walls, where it all ends and how it's labeled are the parts of a network that are hardest to redo. We plan the closet, the panel and every run, and connect you with a licensed contractor to install and test them.
No technical terms needed. Tell us what's wrong or what you're planning; we reply by email with what we'd do and who would do the physical work.
You probably need this when
- The closet is a tangle nobody can trace
- Unlabeled cables, a switch balanced on a shelf, and no way to tell which port feeds which room.
- The gear doesn't fit the panel
- A structured media panel (the shallow recessed box many homes have) holds only small equipment that mounts flat. Rack-mount gateways, rack switches and tower battery backups need a wall rack or a shelf.
- You're adding access points or cameras
- Each one needs its own run back to the closet, and the closet needs ports, power and room to take them.
- An office is moving or being fitted out
- Walls and ceilings are open, which is the cheapest time to put cable where it belongs.
How it works
- List every run first
- A drop schedule names each run, where it starts and ends, and what it's for. It's what installers quote against, and it stops two quotes for "network cabling" from describing different jobs.
- Choose the cable on purpose
- Cable category sets the speed a run is designed for: Cat6 handles 1, 2.5 and 5 Gbps over typical home runs, and Cat6a is designed for 10 Gbps over full-length runs. The plan also specifies solid copper rather than copper-clad aluminum, and the jacket rating the building's code requires.
- Design the closet
- We choose between a media panel, a wall rack and a shelf, and lay out the patch panel (the row of jacks where the in-wall cables end), the switch, power, battery backup and ventilation. The rack power and heat calculator checks the load.
- Labeled, tested and installed by a licensed contractor
- Each run gets one ID, used on the wall plate, both cable ends, the patch panel port and the as-built drawing. The scope sets the test level, from a wiremap to full certification. RouterHaus connects you with a licensed contractor for the work, and you can check their license with the Registrar of Contractors; who and when is confirmed during intake.
What you get
Deliverables
- A drop schedule with every run marked on the floor plan
- Cable specification: category, conductor and jacket rating
- Closet layout: enclosure or rack, patch panel, power, battery backup and heat
- A labeling scheme and a test level for acceptance
- A quote-ready scope for installers
Included
- Planning runs, cable category and closet layout
- Power, heat and battery backup sizing for the closet
- A written scope to compare installer quotes against
- Connecting you with a licensed contractor for the installation
Scoped separately
- Pulling, terminating and testing cable (contractor work)
- New electrical circuits or outlets (an electrician)
- Permits, where a job needs one
- Drywall repair and finishing
In Valley homes and buildings
- Garage closets and summer heat
- Summer temperatures in Valley garages and attics routinely exceed the operating range printed on consumer networking gear. If the panel is in the garage, the cables can end there while the switch and router move into conditioned space.
- Monsoon outages and surges
- Summer storms bring short outages and power surges. A battery backup (UPS) for the closet, and surge protection on long outdoor runs to cameras or outbuildings, keep the network up through brief ones.
- Licensing in Arizona
- Arizona's Registrar of Contractors licenses low-voltage communication work as R-67 for homes, C-67 for commercial buildings and CR-67 for both. Jobs of $1,000 or more, or that need a permit, fall outside the handyman exemption. Our installer hiring guide covers what each class does and doesn't name.
Try it yourself first
Free, and often enough.
- Ethernet cable estimator: cable, boxes, jacks and patch-panel ports for a job, and which category suits the speed.
- Rack power and heat calculator: the power, heat and rack space of a closet's equipment.
- Home network closet design: racks, panels, power and heat
- Hiring a low-voltage network installer: scope, quotes and questions to ask
- How much does structured network wiring cost? An estimating worksheet
What we can help with
From one dead Ethernet jack to a multi-site build-out. Describe it in your own words; you don't need the technical terms.
Homes
- Whole-home Wi-Fi and mesh that reaches every room
- Ethernet wall jacks that don't work, and new runs
- New-home network activation and pre-wire plans
- Network closets and structured-media panels
- Fiber and multi-gig internet setup
- PoE security cameras and smart-home networks
- Home offices that can't drop a call
Businesses
- Retail, restaurant and office Wi-Fi
- Guest, staff and payment networks kept apart
- Structured cabling and network closets
- UniFi, Omada, Meraki and other managed systems
- Camera networks and PoE power planning
- Enterprise and multi-site infrastructure
How the physical work happens
RouterHaus plans the network independently, with no maker paying for the recommendation. When the job needs hands on site, such as pulling cable, mounting access points or building a closet, we connect you with a contractor who fits the work. Which contractor, and when, is confirmed with you during intake, and we tell you about any referral arrangement before you decide.
Request help
Tell us what's wrong
Four short steps: the problem and where it is first, then a few details, then how to reach you. Nothing is sent until you press Send request.
Request received
Thanks. We have your request.
Your reference: . Quote it if you write to us about this request.
We'll reply by email with questions, or with the scope and the price. Nothing is charged until you accept a quote. If you don't hear from us, check your spam folder or write to admin@routerhaus.com.
While you wait, the free troubleshooting steps may already settle it.
Structured cabling and network closets questions
Something else? Ask us and we'll answer by email.
Cat6 or Cat6a?
Cat6 handles 1, 2.5 and 5 Gbps over typical home runs. Cat6a is designed for 10 Gbps over full-length runs, and is worth it for access points, media walls and offices you expect to upgrade. It's thicker and costs more to pull.
What is a structured media panel?
A recessed box in a wall, often in a closet or garage, where the house's Ethernet, coax and phone cables meet. It suits small equipment that mounts flat inside it. Larger gear needs a wall rack or a shelf, and Wi-Fi equipment shouldn't sit inside a metal panel.
Do I need a patch panel?
It's the tidy way to end in-wall cable: each run lands on a numbered jack, and short patch cords connect them to the switch. Plugging solid in-wall cable straight into equipment works but is harder to label, trace and change later.
Wiremap or certification testing?
A wiremap checks that each wire lands on the right pin. Certification measures each run against its category's limits, and is the only test that shows a Cat6a run meets Cat6a. Ask for the results either way.
Does the installer need a license in Arizona?
For a job of $1,000 or more including labor and materials, a job that needs a permit, or one that's part of a larger project, yes. The Registrar of Contractors' low-voltage communication classes are R-67, C-67 and CR-67, and you can check a license in its Contractor Search.
Across the Phoenix metro
Remote planning anywhere, on-site visits by arrangement, and contractors for cabling, installation and commercial work across the Valley.
- Business network installation
- Enterprise and multi-site networking
- Ethernet installation and repair
- Home Wi-Fi and mesh installation
- New-home network setup and pre-wire
- Security camera networks
- UniFi design and installation
Sources
- Arizona Legislature: A.R.S. 32-1121, persons not required to be licensed
- Legal Information Institute: Ariz. Admin. Code R4-9-102, commercial contractor classifications (C-67)
- Legal Information Institute: Ariz. Admin. Code R4-9-103, residential contractor classifications (R-67, R-11)
- Legal Information Institute: Ariz. Admin. Code R4-9-104, dual contractor classifications (CR-67)
- Arizona Registrar of Contractors: Before You Hire a Contractor